Figure 1

Rebar Size

Maximum Rebar Shear

Lip Diameter (A)

in

mm

10 or 12 (#4)

0.57

14.5

14 or 16 (#5)

0.73

18.5

18 or 20 (#6)

0.93

23.5

22 (#7)

1.08

27.5

25 (#8)

1.16

29.4

28 or 30 (#9)

1.32

33.5

32 (#10)

1.48

37.5

34 or 36 (#11)

1.67

42.5

38 or 40

1.83

46.5

43 (#14)

2.07

52.5

57 (#18)

2.62

66.5

Figure 3 Solid contact between bar and stop pin as shown.

Step 3

: Insert rebar into LENTON LOCK coupler until contact

is made with the center stop pin as shown in Figure 3. Rebar
must be flush against center stop pin.

Step 4 for coupler sizes 12(#4) – 36(#11):

For rebar sizes 40 through 57(#18), follow ‘Alternate step 4’ on
the next page.

For Caltrans Ultimate performance on sizes 32(#10) and 36(#11),
also follow ‘Alternate step 4’ on the next page.

To avoid bolts from vibrating loose, it is suggested that each bolt
be pre-torqued (Approximately <50% is recommended torque)
prior to applying final bolt torque.

Tighten bolts, beginning in the center of the coupler and working
to the outside (A to D). A standard wrench, impact wrench or nut
runner may be utilized to tighten the bolts.

Figure 1 Assembly cross section

Figure 2 Maximum shear lip

A B C D

D C B A

TIGHTEN

TIGHTEN

Step 1:

Read all instructions and procedures before

commencing splicing. Ensure the LENTON

®

LOCK coupler is

sized properly for the bars being spliced and per project plans.
Product should arrive with bolts configured as shown in Figure 1.
One round point bolt should be on each end for sizes 10 (#3)
through 40mm. Two round point bolts should be on each end for
sizes 43 (#14) and 57 (#18).

Step 2:

Ensure the rebar is free of any excessive dirt, concrete

slurry, rust, etc. which may affect product performance. Ensure
maximum rebar lip does not exceed limits set in Figure 2.
Excessive shear lip interferes with rebar installation.

*When using an air impact wrench it is recommended to use a wrench with double the torque rating identified. Impact sockets should always be used when using an
impact wrench. Additionally, check the air pressure and air flow requirements prior to installation. Refer to complete installation instructions provided with the product or
available at

www.erico.com

prior to commencing installation.

WARNING

1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at

www.erico.com

and from your ERICO customer

service representative.

2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3. All instructions must be completely followed to ensure proper and safe installation and performance.
4. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death.

The customer is responsible for:

a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.
c. Using appropriate industry standard hardware as noted above.


SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are registered trademarks of ERICO International Corporation

TECHNICAL SUPPORT: PDF116_K 1 of 2

2007, 2008, 2009, 2010, 2012, 2013

www.erico.com

ERICO International Corporation

Advertising