SERVICE (cont.)

TANK HEATER (Cont.)

BLK to Limit Thermostat (120V Models)
Thermal Cut-off to Blu/BLK Lead From
Control Thermostat (220V Two Wire
Models)

WHI to WHI Lead on
Power Cord (120V Models)
Thermal Cut-off to Red
from Power Connector
(220V Two Wire Models)

P1254

FIG. 10 TANK HEATER TERMINALS

THERMAL CUT-OFF - VPRA, VPSA

BUNN

OFF

HI

FIG. 11 THERMAL CUT-OFF

P1270

Location:

The thermal cut-outs are located inside the hood

connected to the tank heater terminals.

Test Procedures:
1.

Disconnect the brewer from the power source.

2.

Disconnect the thermal cut-off from the tank
heater and the red wire from the power connec-
tor.

3.

Check for continuity across the thermal cut-off
terminals with an ohmmeter.

If continuity is present as described, the thermal cut-
off is operating properly.
If continuity is not present as described, replace the
thermal cut-off.

4.

Disconnect the thermal cut-off from the tank
heater and blue/black from the control thermo-
stat.

5.

Check for continuity across the thermal cut-off
terminals with an ohmmeter.

If continuity is present as decribed, the thermal cut-off
is operating properly.
If continuity is not present as described, replace the
thermal cut-off.

Removal and Replacement:
1.

Disconnect the thermal cut-off from the tank
heater and the red wire from the power connec-
tor or the blue/black wire from the control ther-
mostat.

2.

Install new thermal cut-off.

3.

Refer to Fig. 12 when reconnecting wires.

Thermal Cut-off from Tank
Heater to Red Lead from
Power Connector

Thermal Cut-off from Tank
Heater to BLU/BLK Lead
from Control Thermostat

VPRA - VPSA

FIG. 12 THERMAL CUT-OFF TERMINALS

P1269