The insulation test, Why a source four par may give a fail reading, How often to test – ETC Source Four CE PAR EA and MCM User Manual

Page 14

Advertising
background image

12 • CE Source FourPAR

English

The Insulation test

The insulation proves that the internal insulation is in good
condition. You can use standard PAT devices to perform the
insulation test. Follow the steps below to test the luminaire’s
insulation.

1.

Plug the luminaire into the PAT outlet and attach the test clip
to the PAT point on the luminaire.

2.

Set the PAT device to test at 500 volts D.C., then press the
G0/TEST button.

A reading below 1M ohms indicates a possible or imminent
failure. Moisture build-up around the lamp holder or in the
connector or foreign matter accumulated around electrical
connections can cause a low reading.

Why a Source Four PAR may give a fail reading

The majority of appliances must fulfill a ground resistance
requirement of 0.1 ohms or less. Some simple, low-cost PAT
devices assume the 0.1 requirement and do not offer a method
for reading the actual resistance or for setting the fail level to 0.5
ohms. These devices may provide a fail reading for an acceptable
unit if the resistance is slightly above 0.1 ohms. If in doubt, check
with your PAT device supplier and verify that the PAT device can
correctly test a luminaire for the 0.5 ohm condition.

How often to test

Your local regulatory authority has guidelines on the testing
frequency.