ETC Unison Paradigm Central Control Server Setup Guide User Manual

E t c, Unison paradigm, Central control server

Advertising
background image

E T C

®

S e t u p a n d C o n n e c t G u i d e

Unison Paradigm

®

Central Control Server

Paradigm Central Control Server Setup and Connect Guide Page 1 of 4

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2014 ETC. All Rights Reserved.

Product information and specifications subject to change.

7180M2260

Rev C

Released 2014-01

ETC intends this document to be provided in its entirety.

Overview

This setup guide will guide you through the setup and connection of the Paradigm Central Control
Server (P-CCS) in a 19” (1U) rack space mounted bracket.

The Paradigm Central Control Server (P-CCS) manages a Unison Paradigm LightDesigner Server
Project, which can contain many sub-projects. The P-CCS enables server level control events that can
affect all of the configured sub-projects, such as system wide preset activations from a centralized
timed event configuration.

Additionally, the P-CCS provides support for integration of the Unison Paradigm Virtual Touchscreen, a
BACnet IP interface, and provides a built-in web interface for remote connection from a web browser.

I/O Panel Connections

The P-CCS uses two hardware interfaces, each with an I/O panel including the following connections:

• RJ45 connection for interface to the ETC lighting network (Net3 Network)
• five USB ports (one on the front of the unit, four on the rear panel)
• RJ45 connection for interface to a secondary building lighting network (BACnet systems and the

Virtual Touchscreen)

• 12V dc power input (power supplies are provided)

General Use Safety

The P-CCS must be mounted in a rack in a horizontal flat orientation, or placed flat on a desk.

Rack Mount Safety

Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating

ambient temperature of the rack environment may elevate above the room ambient. Special care
should be taken. Do not operate the processor in an enclosed environment above 100°F (40°C).

Reduced Air Flow - When installing the processor in an equipment rack, the rack must be vented

and have adequate airflow to maintain an operating temperature below 100°F (40°C).

Mechanical Loading - Mounting of the equipment in an equipment rack should only be

accomplished using the included ETC rack mount hardware, in a horizontal orientation to assure
even mechanical loading in the rack; avoiding hazardous or dangerous loading conditions.

Circuit Overloading - Use only the supplied ETC power supplies of 12V dc / 5A to power the

processor. When installed in an equipment rack, consideration should be given to the connection
of the processor to the rack or power source to avoid overloading the rack circuit or supply wiring.
Appropriate consideration of the rack or power distribution in the equipment rack should be
applied during installation.

Reliable Grounding - Reliable earthing of the rack-mounted equipment should be maintained.

Particular attention should be given to any supply connections other than direct connections to the
branch circuit (e.g. use of power strips).