ETC EchoConnect Cat5 Termination Tray User Manual

E t c, Unison, Echoconnect cat5 termination tray

Advertising
background image

E T C

®

I n s t a l l a t i o n G u i d e

Unison

®

EchoConnect Cat5 Termination Tray

EchoConnect Cat5 Termination Tray Installation Guide

Page 1 of 2

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2014 ETC. All Rights Reserved.

Product information and specifications subject to change.

7186M2201

Rev A

Released 2014-05

ETC intends this document to be provided in its entirety.

Overview

This EchoConnect Cat5 termination tray is intended for
installation on the rear panel of the Echo Rack Mount
Station Power Supply (E-SPM-RM).

Use this termination tray to facilitate termination of up to
16 runs of Category 5 (or equivalent) cable on the
EchoConnect communication bus.

The following supplies are included for installation
convenience:

• 6.25” (15cm) of 2 conductor black/white wire
• 11” (28cm) ESD ground with Faston connector
• 4 x mounting screws
• Six position screw terminal connector J3263-F (x1)

Mount Tray to Rear Panel

The termination tray installs to the rear panel of the Echo
Rack Mount Station Power Supply. Secure the
termination tray to the rear panel using the four mounting screws provided.

Terminate Wires

This termination tray, as well as the rear panel of the Rack Mount Station Power Supply are provided
with wire forms to secure wires with cable ties. Cable ties are not provided but highly recommended to
use in maintaining the wire bundles.

Terminations include:

• EchoConnect between this termination tray and the Echo Rack Mount Station Power Supply.
• Up to 16 runs of Category 5 (or equivalent) cable between this termination tray and Echo control

stations.

• ESD ground wires terminate to the ground bar on the rear panel of the station power supply. This

connection is required for all stations that are not installed entirely in grounded metal conduit.

6.25” (15.8cm)
included

11” (28cm)
included

(16) Cat5 inputs

EchoConnect - white/black

twisted wire connects

between the 6 position

connector on the tray and

the 2 position connector on

the power supply.

ESD ground wire with Faston

connects between tray and ESD

ground bar on the power supply

Advertising