Iec component transfer – ETC Sensor+ CE Rack (ESR+) CEM+ to CEM3 Retrofit User Manual

Page 9

Advertising
background image

2

The Retrofit

7

IEC Component Transfer

(IEC ONLY) You must transfer the components from the

NEFM slot to the new backplane.

a: Using a small blade screwdriver, press the

locking tabs for the plastic cable grommet

inward one-at-a-time and then push the

grommet out of the old backplane.

b: From the front face of the backplane, insert

the cable grommet into the appropriate

round hole in the new backplane and press

until the tabs lock it in place.

c: Using a #2 Phillips screwdriver, remove the two screws that retain the female

IEC connector in place. Be sure to catch the nuts after the screws have been

removed. You will need the screws and nuts to secure the IEC connector in the

new backplane.

d: Insert the IEC connector into the new backplane in the orientation shown.

Secure it using the two screws and two nuts removed in the previous step.

e: Attach the green/yellow earth wire to the PEM stud on the rear of the new

backplane and ensure that the other end is still fully connected to the rear of

the IEC connector.

Step 13: Once you have performed all of the above steps, discard the old backplane in

accordance with local regulations.

Save nuts