ETC Net3 Four Port DMX Gateway User Manual

Four-port gateway setup guide, Overview, Dmx gateway modules

Advertising
background image

Four-Port Gateway Setup Guide

Corporate Headquarters 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736

London, UK Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK Tel +44 (0)20 8896 1000 Fax +44 (0)20 8896 2000

Rome, IT Via Pieve Torina, 48, 00156 Rome, Italy Tel +39 (06) 32 111 683 Fax +44 (0) 20 8752 8486

Holzkirchen, DE Ohmstrasse 3, 83607 Holzkirchen, Germany Tel +49 (80 24) 47 00-0 Fax +49 (80 24) 47 00-3 00

Hong Kong Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Tel +852 2799 1220 Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2011 ETC. All Rights Reserved. Product information and specifications subject to change.

4260M2201

Revision A 2011-05

Page 1 of 2

Four Module Bays

• use any combination of modules

including the blank plate, DMX

Out (XLR Female), DMX In (XLR

Male), RJ45 and terminal strip

modules.

Strain Relief

• strain relief clip for

dc power cable

Grounding Post

DC Power Input

• 8-28Vdc

• Positive tip

• 3.5mm barrel

• 5 Watts usage

Overview

This Setup Guide will guide you through the setup of the Net3 Four-Port DMX/RDM gateway (version 5.x software and later)

including hardware, electrical and data connections. Software configuration of your gateway is covered separately and relates

specifically to the software versions that may be running in the gateways.

• For

Net3 configuration, please refer to the Gateway Configuration Editor (GCE) Online Help System.

DMX Gateway Modules

There are four different modules available for use in the Four-Port gateway: DMX Out (5-pin female), DMX In (5-pin male),

RJ45 (8-pin female for input or output) and DMX Terminal Strip (8-pin Weidmuller for input or output).

• The terminal strip module comes with ETC’s standard DMX termination preparation kit (part number 4100A012) which includes instructions and

all parts required for installation. If you are connecting to Category 5 wire for DMX, request the DMX termination preparation kit with IDC

connectors from ETC (part number 4100A1013).

• The DMX RJ45 module can use a standard Category 5 cable to transmit DMX512 to other devices utilizing the same connector.

NOTE:

The DMX RJ45 module will not function as an Ethernet network port.

Any of these modules may be configured as DMX input or DMX output using configuration software. Additionally, there is a blanking plate for any

unused module bay.

WARNING: RISK OF ELECTRIC SHOCK! Power must be removed from the gateway before removing any modules or covers to

service the unit.

With power removed from the Gateway, you can move and swap DMX modules as needed for required configuration or replacement.

Help from ETC Technical Services

If you experience difficulty during setup or installation of the Net3 gateway, additional information is available from

www.etcconnect.com

, or by

contacting ETC Technical Services at your local office listed on the bottom left side of this document.

DMX Basics and Pin-Outs

The Net3 Four-Port gateway sends and receives DMX512 control signals. This unit can contain up to four DMX ports in any combination

using 5-pin DMX input connectors, 5-pin DMX output connectors, RJ45 connectors, or terminal strip connectors. DMX cables must be

acceptable for DMX data transmission (not microphone cable) and connections should follow the standard pinouts per the charts below.

The optional secondary data pair is not used by the Net3 Four-Port gateway.

Ethernet Connection

• PoE (IEEE 802.3af)

• 10/100Mbps data speeds

• Auto-sensing

• Auto-negotiation

• RJ45 and etherCON compatible

Reset Button

• hard reboot

Menu Button

• Activates the LCD backlight

• Advances display pages

LCD

• Displays gateway status

and configuration data

Activity Indicator

• Solid green LED indicates

network connection.

• Flashing LED indicates

network activity

Power Indicator

• Solid blue LED

indicates power

Activity Indicator

• Solid green LED indicates

network connection.

• Flashing LED indicates network

activity

Power Indicator

• Solid blue LED

indicates power

Retaining Screw

• secures the module

in the gateway

Pull Tab

• for easy module removal

Protective Cover

• protects delicate

electronics

DMX Termination

• switch directly behind the

connector for convenience

DMX Out Module

(XLR 5-pin female)

DMX In Module

(XLR 5-pin male)

DMX RJ45 Module

(RJ45 8-pin female)

DMX Terminal

Strip Module

(8-pin male)

1

8

DMX512 Pinout for 5-pin XLR Connectors

Pin#

Use

Common

(shield)

Data -

Data +

unused

unused

1

2

3

4

5

Female (output)

Male (input)

Common (shield)

Data -

Data +

unused

unused

unused

unused

unused

Clear/Shield

Black

Red

DMX512 Pinout for RJ45 Connectors

DMX512 Pinout for Terminal Strip Connector

Pin#

Use

Data 1 -

Data 1 +

not used

not used

not used

not used

1

2

3
4

5

Female

Female

Wire Color

Pin#

Use

Wire Color

Signal Common

Signal Common

Orange

White/Orange

White/Green

Blue

White/Blue

Green

Brown

White/Brown

6

7

8

1
2

3
4
5
6

7

8

Push

1

2

3

4

5

1

2

3

4

5

Push

1

8

Advertising