ETC Unison Heritage Button Station User Manual

Unison heritage button station, Overview, Installing the heritage button station

Advertising
background image

E T C I n s t a l l a t i o n G u i d e

Unison Heritage Button Station

Unison Heritage Button Station

Page 1 of 4

Electronic Theatre Controls, Inc.

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0)20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2012 ETC. All Rights Reserved.  Product information and specifications subject to change.

7181M2100  Rev D  Released 2012-02  ETC intends this document to be provided in its entirety.

Overview

The Unison

®

Heritage Button Station connects to the LinkConnect station

communication bus. LinkConnect is based on Echelon

®

LonWorks™ with

LinkPower bidirectional protocol, and uses one pair of wires (data+, data–).

LinkPower is topology free and polarity independent; you can install your
LinkPower data runs in any desired combination of bus, star, loop, and home-run.
ETC recommends using Belden 8471 (or approved equal) wire. The total
combined length of a LinkPower wire run may not exceed 1,640 feet (500m), with
a maximum distance of 1,312 feet (400m) between any two devices. The Heritage
Button Station may be installed into an industry standard single gang backbox
(provided by others) or a surface mounted backbox (sold separately and available
from ETC).

All control wiring should be installed and terminated by a qualified installer and
should follow standard wiring installation practices. Leave approximately 10 inches
(254mm) of wiring in the backbox for connection and to allow slack for future
service needs.

Installing the Heritage Button Station

Installation should follow local codes
and standard practices. The backbox
should be installed square for best
results. Ensure that the backbox is clean
and free of obstructions and that all
wiring is installed correctly.

Heritage stations ship with a termination
kit containing a LinkPower pigtail, a
ground wire pigtail, spacers, and all
required connectors for installation.

Heritage Button Station Surface Backbox

Model

Description

-1S

Unison 1Gang surface mount backbox

-2S

Unison 2Gang surface mount backbox

N o t e :

ETC requires that all stations be grounded by using grounded

metal conduit or a 14 AWG (2.5mm

2

) ESD drain wire.

LinkPower

pigtail

Ground

pigtail

WAGO

Spacers