Operating instructions safety switch np – EUCHNER NP User Manual

Page 5

Advertising
background image

Operating Instructions Safety Switch NP

EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]

Subject to technical modifications; no r

esponsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. KG

083684-06-12/10

(translation of the original operating instructions)

Figure 7: Dimension drawing NP1-...AS

M20 x 1,5

M4 (2x)

Figure 8: Dimension drawing NP1-...AB

M20 x 1,5

Version NP3... (Plug connector M12)

Conductor cross-section 0.25 mm².

Fig. 6: Plug connector M12 terminal assignment

Functional check

Warning! Danger of fatal injury as a result of faults
in installation and functional check.

Before carrying out the functional check, make
sure that there are no persons in the danger
area. Observe the valid accident prevention
regulations.

After installation and any fault, the safety function must
be fully checked. Proceed as follows:

Mechanical function test

The actuator must slide easily into the actuating head.
Close the safety guard several times to check the
function.

Electrical function test

1. Switch on operating voltage.
2. Close all safety guards.

The machine must not start automatically.

3. Enable operation in the control system.
4. Open the safety guard.

The machine must switch off and it must not be
possible to start it as long as the safety guard is
open.

Repeat steps 2 - 4 for each safety guard.

Inspection and service

If damage or wear is found, the complete switch
and actuator assembly must be replaced.

Replacement of individual parts or assemblies
is not permitted!

No servicing is required, but regular inspection of
the following is necessary to ensure trouble-free long-
term operation:

correct switching function
secure mounting of components
dirt and wear
sealing of cable entry
loose cable connections or plug connectors.

Note:The year of manufacture can be seen in the
bottom, right corner of the rating plate.

Exclusion of liability under the following
circumstances

incorrect use
non-compliance with safety regulations
installation and electrical connection not performed
by authorized personnel.
failure to perform functional checks.

1

4

3

2

12

11

2

1

4

22

21

638

3

View of connection

side

EC declaration of conformity

The manufacturer named below herewith declares that
the product fulfills the provisions of the directive(s)
listed below and that the related standards have been
applied.

EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen, Germany

Directives applied:

Machinery directive 2006/42/EC

Standards applied:

EN 60947-5-1:2004 + Cor.:2005 + A1:2009
EN 1088:1995+A2:2008

Leinfelden, July 2010

Dipl.-Ing. Michael Euchner
Director

Duc Binh Nguyen
Authorized representative empowered to draw up
documentation

The signed EC declaration of conformity is included
with the product.