Technical Data

Parameter

Value

Unit

min.

typ.

max.

Housing material

Fortron, reinforced thermoplastic, fully encapsulated

Dimensions

50 x 50 x 20.2

mm

Weight

0.08

kg

Ambient temperature

-25

-

+70

°C

Degree of protection

IP67

Installation position

Any

Method of operation

Inductive

Power supply

Via evaluation unit

In combination with actuator CES-A-BBA or CES-A-BCA

Assured switch-off distance S

ar

-

-

47

mm

Operating distance for center offset m = 0

1)

- Switch-on distance

-

15

-

- Assured switch-on distance S

ao

10

-

-

- Switching hysteresis

2

3

-

In combination with actuator CES-A-BQA on evaluation unit CES-A-UBA-01B

Assured switch-off distance S

ar

-

-

60

mm

Operating distance with vertical approach direction

Center offset m = 0

1)

- Switch-on distance

-

23

-

- Assured switch-on distance S

ao

16

-

-

- Switching hysteresis

2

3

-

Operating distance with side approach direction

Distance in x direction = 10 mm

- Switch-on distance

-

28

-

- Assured switch-on distance S

ao

24

-

-

- Switching hysteresis

1

1.3

-

Connection cable

-

-

25

m

1) These values apply for surface installation of the read head and the actuator.

Ordering table

Series

Cable/connection type

Comment

Order no. / item

CES-A-LQA-SC

SC

M8 plug connector

2 safety screws M4 x 14 are supplied

095650

CES-A-LQA-SC

H11 H12

SH1

BN

WH

1

4

3

Screen

Read head

Evaluation unit

CES-A-UBA-...

Advertising