Operating Instructions Safety System CES-AZ-ABS-01B

26

Pin assignment

Read head with connection cable

Technical Data

Parameter

Value

Unit

min.

typ.

max.

Housing material

Plastic PE-HD without reinforcement, fully encapsulated

Flat seal material

Fluororubber 75 FPM 4100

Dimensions

42 x 25 x 12

mm

Weight (incl. 10 m cable)

0.3

kg

Ambient temperature

-25

-

+50

°C

Degree of protection

IP67/IP69K

Installation position

Any

Method of operation

Inductive

Power supply

Via evaluation unit

In combination with CES-A-BCA actuator

Assured switch-off distance S

ar

-

-

26

mm

Operating distance for center offset m = 0

1)

- Switch-on distance

-

15

-

- Assured switch-on distance S

ao

10

-

-

- Switching hysteresis

0.5

2

-

Minimum distance s with lateral approach direction

-

3

-

In combination with actuator CES-A-BDA

Assured switch-off distance S

ar

-

-

33

mm

Operating distance for center offset m = 0

2)

- Switch-on distance

-

16

-

- Assured switch-on distance S

ao

11

-

-

- Switching hysteresis

0.5

2

-

Minimum distance s with lateral approach direction

-

4

-

Connection cable

Hard-wired encapsulated connection cable, with crimped ferrules

PVC,

∅ 4.6 mm

Cable length

-

-

25

m

1)

These values apply to non-flush installation of the read head and actuator.

2)

These values apply to metal-free surrounding material. Other materials on request.

Ordering table

Series

Cable/connection type

Cable length "l" [m]

Order no. / item

CES-A-LCA...

V

Cable PVC

10

088785

CES-A-LCA-10V

H11 H12 SH1

BN

WH

Screen

View

on plug connector

of the read head

Evaluation unit
CES-AZ-ABS-...

Read