Inspection and service, Service, Operating instructions safety system ces-az-als – EUCHNER CES-AZ-ALS-xxx (Unicode) User Manual

Page 48

Advertising
background image

Operating Instructions Safety System CES-AZ-ALS-...

48

Inspection and service

Warning!

Loss of the safety function because of damage to the system.
In case of damage, the related safety component must be replaced. The replace-
ment of individual parts in a safety component is not permitted.

Regular inspection of the following is necessary to ensure trouble-free long-term
operation:

Ì

Check the switching function (see section Functional check)

Ì

Check the secure fastening of the devices and the connections

Ì

Check for soiling

Ì

Check for sealing of the plug connector on the safety switch

Ì

Check for loose cable connections on the plug connector.

Ì

Check of the switch-off distance

No servicing is required, repairs to the device are only allowed to be made by the
manufacturer.

Note:

The year of manufacture can be seen in the lower right corner of the rating plate.

The current version number in the format X.X.X. can also be found on the device.

Service

If service support is required, please contact:

EUCHNER GmbH + Co. KG

Kohlhammerstraße 16

D-70771 Leinfelden-Echterdingen

Service telephone:

+49 711 7597-500

E-mail:

[email protected]

Internet:

www.euchner.de