Bunn DUAL TM (Serial # DUAL010000 - Up) 27040.0000F User Manual

Page 13

Advertising
background image

Page 13

TROUBLESHOOTING (cont.)

Problem

Weak beverage (cont.)

Brewer is making unusual noises.

Probable Cause

3. Sprayhead

4. Funnel loading

5. Water temperature

1. Solenoid (Inlet)

2. Plumbing lines

3. Water supply

4. Tank Heaters

5. Contactor

Remedy

A clean sprayhead should be used to
properly wet the bed of ground cof-
fee in the funnel.

The BUNN

®

paper filter should be

centered in the funnel and the bed of
ground coffee leveled by gentle shak-
ing.

Empty the server, remove its cover,
and place the server on the warmer.
Place empty funnel over the server
entrance, with ON/OFF switch in the
"ON" position press the start switch
and release it. Check the water tem-
perature immediately below the
sprayhead with a thermometer. The
reading should not be less than
195˚F(91˚C).

The nut on back of the solenoid
must be tight or it will vibrate during
operation

Plumbing lines should not be rest-
ing on the counter top.

(A) The brewer must be connected
to a cold water line.

(B) Water pressure to the brewer
must not be higher than 90 psi (620
kPa). Install a regulator if necessary
to lower the working pressure to
approximately 50 psi (345 kPa).

Remove and clean lime off tank heat-
ers.

Check for low voltage

27040 011904

Advertising