Operating Instructions Safety System CES-AP-C.2-AH

12

Connector assignment and wire color for safety

switch CES-AP-C.2-AH

plug connector with latching connection, 6-pin

Fig. 1: Connector assignment, plug connector with latching connection

Pin Designation

Description

Wire color

1

UB

Power supply, DC 24 V 

BN

2

OA

Safety output, channel 1

WH

3

0V

Ground, DC 0 V

BU

4

OB

Safety output, channel 2

BK

5

OUT

Door monitoring output

GY

6

-

Not used

PK

Connection cable with M12 plug connector, 5-pin

Fig. 2: Connector assignment, connection cable with M12 plug connector

Pin

Designation

Description

Wire color

5-pin

5-pin

Pin 5

not

used

1

1

UB

Power supply, DC 24 V 

BN

2

2

OA

Safety output, channel 1

WH

3

3

0V

Ground, DC 0 V

BU

4

4

OB

Safety output, channel 2

BK

5

-

OUT

Door monitoring output

GY

View on the connection side of the safety switch

S1.1

S1.3

S1.6

S1.2
S1.4
S1.5

+UB

0V

NC

OA
OB
OUT

5

1

4

6

2

3

Coding lug

View on the connection side of the safety switch

S1.1

S1.3
S1.2
S1.4
S1.5

+UB

0V
OA
OB
n.c.

4

1

5

2

3

S1.1

S1.3
S1.2
S1.4
S1.5

+UB

0V
OA
OB
OUT

Coding lug

5-pin

5-pin,

pin 5 not used