E.g. et200pro series from siemens), Operating instructions safety switch ces-ap-c01-ch, Figure 3: example of incorrect connection – EUCHNER CES-AP-C01-CH (Multicode) User Manual

Page 14

Advertising
background image

Operating Instructions Safety Switch CES-AP-C01-CH

14

Warning!

In the event of a fault: Loss of the safety function due to incorrect connection.

Ì

To ensure safety, both safety outputs (OA and OB) must always be evaluated.
Single-channel use of the safety outputs leads to a loss of the category in
accordance with EN ISO 13849-1.

GND

DC 24 V

CES-AP-C

n.c.
1

UB
2

OA
3

OB
4

M12 plug-connector

(8-pin)

DIA
5

n.c.
6

0V
7

RST
8

-K1

-K2

-M1

-M2

M

M

A1

A2

A1

A2

13

14

13

14

Figure 3: Example of incorrect connection

Connecting CES-AP-...-SB-... (pin 5 not assigned) to

a decentralized peripheral system (e.g. ET200pro

series from Siemens)

Observe the information in the section Particularities for operation on decentralized

peripheral systems on page 11 before connecting the device.

Figure 4: Connection example for connection to decentralized peripheral sys-

tems

CES-AP-...-SB-...

U

B

1

FO1A

2

0V

3

FO1B

4

S1: M12 plug-connector

(5-pin)

n.

c.

5

decentralized

periphery

e.g. ET 200pro

PLC

DI

1

5

2

4

3

1 5

2

4

3

DO