Operating instructions for emergency stop switch ES-FB1W-XW

SAFETY NOTE

Turn off the power to the control unit before starting installation, removal,

wiring, and maintenance. Failure to turn power off may cause electric shocks

or fire hazard.

Use wires of a proper size to meet voltage and current requirements. Tighten

the terminal screws to recommended tightening torque. Improper wires and

loose terminals during operation will cause overheating and fire hazard.

Provide a proper protection against electric shocks.

Failure to turn power off may cause electric shock or fire hazard.

Mounting

Panel Mounting

1. Installing the FB series control box from the front

Use two M4 screws. (Recommended tightening torque: 1.4 to 2.0 Nm)

Determine the screw length in consideration of the box base and panel

thickness.

The cable is connected to the emergency stop switch on the box cover side with

a removable connector. To separate the box base and box cover completely,

remove the connector. This connector is equipped with a lock to prevent dis-

connection. Pull the connector while pressing the locking knob.

62

41

21

2-φ

4.6

4 M4 tapping holes for rear mouting (depth: 10 mm)

2 front mouting holes

2. Installing the FB series control box from the back
When installing from the back, insert M4 tapping screws into holes for the

tapping screws on the back of the box base (depth: 8 to 10 mm, tapping screw

hole diameter: Ø3.7 mm) [Recommended tightening torque: 1.3±0.1Nm.

3. Installation using accessories (FB9Z-PK1)
When using accessories for installation, refer to each instruction sheet.

Installing and removing the control unit

Refer to installation instructions for each control unit.

Installing a cable gland

Break a desired knockout to mount a cable gland using a hammer and a

screwdriver, and install the cable gland. When breaking the knockout to open

a cable gland hole, be careful not to damage the internal contact block.

Note that cracks or burrs on the cable gland hole will degrade the waterproof

characteristics.

Installing the box cover and box base

Attach the box cover to the box base so that the TOP mark on the box cover

and box base are in the same direction.

Use box cover mounting screws to attach the box cover to the box base.

(Recommended tightening torque: 1.3±0.1 Nm)

Make sure that the box cover and the box base are attached in the correct

direction. Otherwise, the ES-FB series control box may be damaged.

Addressing

M12 connector type

The address setting device with an „M12 AS-i line connector,“ enabling direct

connection of the M12 connector. The address can be set from this state.

Pin Assign

Wiring

M12 connector type

Connect one end of the special cable with M12 connector cable for ES-FB -XW

that is sold separately and the other connector to AS-Interface flat cable.

Applicable Wire

Determine the wire size in consideration of the control unit and cable thickness

of the cable gland.

When using plastic cable gland and multi-core cable

Gland port size

Plastic cable gland

M20

5311 1220 (Skintop-ST-M), Applicable gasketGPM20 (LAPP, Germany)

G1/2

5380 6030 (Skintop-ST-PF), Applicable gasketGP 050 (LAPP, Germany)

PG13.5

5301 5030 (Skintop-ST), Applicable gasketGP13.5 (LAPP, Germany)

Locking nut for installing cable gland

(The locking nut for installing cable gland is not supplied. Order separately.)

Only UL approved cable glands are described.
When using the ES-FB control box in North America, be sure to use UL approved

plastic cable glands.

Tighten cable glands to a torque of 3.0±0.3Nm.
Insufficient tightening of the cable gland may degrade the waterproof characteristics.
Electric shock protection Class II is maintained only when a plastic cable gland is

used.

Determine the cable gland for a multi-core cable according to the outside diameter

of the cable sheath.

When wiring from the back of ES-FB series control box, use the Ø14 knockout on the

back of the control box. A cable gland cannot be installed to the Ø14 knockout.

Function

ES-XN/XW series emergency stop switches feature a slave connection to the

safety bus AS-Interface Safety at Work.The position monitoring of the safety

guard is carried out with two positively driven contacts.
When the button is in normal position it transmits a switch-specific, unique

safety code sequence with 8x4 bits via the AS-Interface. This code sequence

is evaluated by an AS-Interface safety monitor. The first positively driven NC

contact is represented by the AS-Interface input bits D0 and D1, while the

second positively driven NC contact is represented by D2 and D3.
The switch-specific safety code sequence is transmitted via the AS-Interface

input bits D0 to D3 when the safety guard is closed.
When the button is pushed, the values 0, 0, 0, 0 are transmitted in every bus

cycle by D0 to D3. The emergency stop switch must be configured correspon-

dingly in the AS-Interface safety monitor (refer to the operating instructions of

the AS-Interface safety monitor used).

Notes for Operation

Wiring

Avoid foreign objects such as dust, liquid, and oil from entering the switch

while wiring.
Do not twist or pull the cable or cable gland with excessive force.

Otherwise, the wire, ES-FB series control box, and control units may be

damaged.
Because the ES-FB series control box is not provided with a PG

terminal, a bonding circuit cannot be interconnected.

Operation

Avoid any contact with oil or coolants. Otherwise, the control box may

be damaged.
Use ES-FB-series control box indoors.