Manual EKS ActiveX

®

Module serial / USB

4 Examples

Information!
The installation CD contains examples for the integration of the EKS ActiveX

®

module in various

programming environments.

4.1 Establishing connection with the EKS Electronic-Key adapter

The following example shows how the method Open can be used. The values shown correspond to the default
settings for the properties. It may be necessary to change these values for your application.

1. Set required values in the properties. These settings can also be made in the programming tool (e.g. Visual

Basic

®

) using the properties of the object EKS:

EKS.Port = "COM1"

EKS.BaudRate = EKS_BAUD_9600

EKS.KeyType = EKS_KEY_READWRITE

EKS.PollingTime = 0

2. Set the required read/write parameters (can also be set after opening the interface):

EKS.StartAdress = 0

EKS.CountData = 4

3. Open

serial

interface:

EKS.Open

Information!
If the default values shown are used, it is sufficient to use just the one line with the call EKS.Open.