4 laststate (readonly), Manual eks activex, Module ethernet tcp/ip – EUCHNER ActiveX Module Ethernet TCP/IP User Manual

Page 11

Advertising
background image

Manual EKS ActiveX

®

Module Ethernet TCP/IP

3.5.4 LastState (ReadOnly)

 Description

Status of the last method called (0=OK or status number)

 Syntax

long = object.LastState;

 Comments

After a method is run (Read, Write, …) or after an event (OnKey, OnRead, ...), you can
determine here whether the method was run correctly. Status numbers in the range
from 0 to 127 (0

hex

to 7F

hex

) are generated by the EKS and are documented in the

manual for the EKS Electronic-Key adapter. Status numbers between 128 and 255
(80

hex

to FF

hex

) are generated by the ActiveX

®

module.

 Data

type

long

 List of status numbers for the ActiveX

®

module:

Attention!
Immediately after a method has been called or an event has been triggered you should poll the value
in the property LastState. Otherwise the property LastState could be overwritten by another method,
as only the status message from the last method run is given in the property LastState. This warning
also applies to internal methods that run in the background and that are not started by you.

Value Description

hex dec

0x90 144 WrongParam

The TCP port given in the property Port is not is the range >1024 und <65535

0xA0 160 DeviceNotOpened

The connection to the EKS has not been opened, please run the method Open.

0xB0 176 ReadTimeOut

It was not possible to correctly complete the method Read, the method has timed out.

0xB1 177 WriteTimeOut

It was not possible to correctly complete the method Write, the method has timed out.

0xB2 178 TimeOut

An internal method in the ActiveX

®

module has timed out.

0xC0 192 NothingToRead

The number of bytes of data to be read, as defined by the property CountData, is 0.

0xC1 193 NothingToWrite

The number of bytes of data to be written, as defined by the property CountData, is 0.

0xE0 224 OpenFailed

The method Open failed.

0xE1 225 OpenActive

The method Open is still active.

0xE8 232 Suspend

The computer will be placed in the suspend mode.

0xE9 233 ResumeSuspend

The suspend mode has been terminated.

0xEA 234 ConnectionTimeOut

Connection timeout to the EKS. It was not possible to establish a connection to the EKS in the time specified.

0xEB 235 ConnectionLost

The connection to the EKS has been interrupted.

0xEC 236 Reconnect

The connection to the EKS has been re-established.

0xFF 255 Busy

The ActiveX

®

module is busy processing a method, the request cannot be run.

102030-02-10/12

Subject to technical modifications

Page 11

/