Warning, Caution – Bryant LEGACY LINE--RNC T1--PHP User Manual

Page 2

Advertising
background image

2

Thermostat should NOT be mounted:

S

Close to a window, on an outside wall, or next to a door leading
to the outside.

S

Exposed to direct light and heat from the sun, a lamp, fireplace,
or other heat--radiating object which may cause a false reading.

S

Close to or in direct airflow from supply registers and return--air
grilles.

S

In areas with poor air circulation, such as behind a door or in an
alcove.

Step 2 — Install Thermostat

ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing thermostat, turn off all power to unit. There

may be more than 1 disconnect. Lock out and tag switch with

a suitable warning label.

!

WARNING

1. Turn OFF all power to unit.
2. If an existing thermostat is being replaced:

a. Remove existing thermostat from wall.

b. Disconnect wires from existing thermostat, one at a

time. Be careful not to allow wires to fall back into wall.

c. As each wire is disconnected, record wire color and

terminal marking.

d. Discard or recycle old thermostat.

ENVIRONMENTAL HAZARD
Failure to follow this caution may result in environmental

damage.
Mercury is a hazardous waste. Federal regulations require that

Mercury be disposed of properly.

CAUTION

!

3. Separate front and back plastic assembly of thermostat.
4. Route thermostat wires through hole in mounting base.

Level mounting base against wall (for aesthetic value only,

thermostat need not be level for proper operation) and mark
wall through 2 mounting holes.

5. Drill two 3/16--in. mounting holes in wall where marked.
6. Secure back plate to wall with 2 anchors and screws

provided making sure all wires extend through hole in

plastic.

7. Connect wires to proper terminal location on backplate.
8. Push any excess wire back into wall. Seal hole in wall to

prevent air leaks. Leaks can affect thermostat operation.
Any excess wire left inside thermostat casing may also

affect thermostat operation by interfering with airflow
across the temperature sensor.

9. Snap thermostat together making sure assembly is secure.

10. Turn ON power to unit.

On power up, depending on the thermostat model being used, the

LCD readout will display either AC for air conditioner model
(1--stage heat/1--stage cool) or HP for heat pump model (2--stage

heat/1--stage cool).

Step 3 — Set Thermostat Configuration

Configuration options enable the installer to configure the
thermostat for a particular installation.
These are not presented to the homeowner and therefore must be

properly set by the installer. Following is a list of the options
available, an explanation of their function, and their factory default

settings. Not all numbers are used in the Legacy Line--RNC Series
because not all options are available in this series.

Configuration Options -- Summary:

Option 01 -- Equipment type
Option 03 -- Fahrenheit/Centigrade
Option 04 -- Fan (G) on with W output
Option 10 -- Reversing valve
Option 13 -- Room air temperature offset
To Enter The Configuration Mode:
Press and hold the FAN key for about 10 seconds until the display

changes so that only two pairs of digits are showing. The
configuration

number,

now

01,

will

appear

in

the

setpoint/temperature location and the configuration setting will

appear in the clock location. The configuration number (left pair)
will be flashing which means it can be adjusted using the UP and

DOWN keys. To cause the opposite pair to flash (to be adjustable),
press the H/C key. Successive presses of the H/C key alternate

between the configuration number (left) and the configuration
setting (right). To exit the configuration mode, press the

HOLD/END key. If no key is pressed for 3 minutes, the

configuration mode will automatically exit, returning the
thermostat to normal operation.

Configuration Options -- Selection:

Option 01 -- Equipment type
Selections: with HP thermostat: HP, AC, PH, or PC

with AC thermostat: AC or PC

Meanings:
PH or PC selects PTAC units (Packaged Terminial Air

Conditioners) which are used in motel rooms and other rented
spaces. When this option is selected, the display shows only the

setpoint, not the room temperature. Also, the compressor
timeguard is disabled, allowing the compressor to turn on

immediately when a demand is established.
HP or PH controls 1 speed heat pump with 1 stage of aux heat.
AC or PC controls 1 speed air conditioner with one stage of heat.
Note that this option allows a HP thermostat to be converted to
control an AC system.
Option 03 -- Fahrenheit/Centigrade
Selections: F = Fahrenheit — This is default.

C = Centigrade.

Selects temperature display units.
Option 04 -- Fan (G) ON with W output
Selections: OF = G not energized with W — This is default.

ON = G energized with W.

This selection determines whether the fan (G) is to be ON or OFF

when the W (furnace or strip heat) is ON. Furnaces and fan coils

which manage their own blowers do not require a separate G
signal. Some auxiliary heaters require a separate G signal to operate

the blower when W is applied.
This option allows a HP thermostat to control an AC system.
Option 10 -- Reversing valve
Selections: C = reversing valve energized in cooling —This is

default.
H = reversing valve energized in heating — Only
appears in HP systems.

T1

--

PA

C

/T1

--

PH

P

Advertising