Application

High out-put ventilation for confined spaces and ideal for improving breathing conditions in hazardous
locations:

* Shipyards
* Cargo Tanks
* Vessels
* Navy Ships

* Railroads
* Tank Cars
* Construction Sites
* Crawl Areas

* Steel Mills
* Refineries
* Chemical Plants
* Manufacturers

* Paper Mills
* Equipment that needs cooling
* Aircraft Maintenance areas
* Manholes

Operation

Powered by compressed air or saturated steam

Operate these air movers on compressed air or saturated steam lines limited to pressures of 100 PSI

Operates on the Venturi principle of using small volumes of high velocity air (from a compressed source)
pushing the air through the cone body creating entrained air (pulling action) that induces large volumes of
low velocity air through the cone and out the air diffuser

The only set up required is running a line from the compressor or steam source and connecting it to the
inlet fitting

Fits standard 3” and 6” API openings

Anti-Static with a crush proof conductive polymer diffuser

Weather proof and chemical resistant

No moving Parts - minimum maintenance and lightweight for easy portability

Optional Static Cord, pressure gauge available

Safety Precautions

Due to the high reaction force, be sure to firmly position and secure unit before turning on the air supply.

Keep area free of loose debris or solid objects to prevent them from entering the inlet housing.

Prevent clogging of the nozzle jets, and periodically steam clean them for proper maintenance.

Warning!

Connect only to compressed or saturated steam lines limited to pressures of 100 psi.

Connection of this product to pressure lines should be restricted to qualified personnel.

Properly ground this product to prevent static discharge when used in areas containing
combustible gas, vapor, or dust.

Do not drag the aluminum base of this product across steel which can create a smear. A heavy smear, when
struck with some object, can cause an incendiary spark.

Warranty

Portable Blowers: Portable Blowers are warranted against defects in material and workmanship for a
period of one year from the date of original purchase. Duct is not warranted due to its intended use. *
* Authorization for warranty repairs must be obtained from the factory. There are no other
warranties expressed or implied.

RAMFAN corporation - Spring Valley, CA USA Call 619-670-9590