OPERATING INSTRUCTIONS

13.5kW Hs INLINE HEATER

HA02/HA03

Please retain these instructions for future reference.

General Hazard Warning

Failure to comply with the precautions and instructions provided with this heater, can result in
death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn,
asphyxiation, carbon monoxide poisoning, and/or electrical shock.

Only persons who can understand and follow the instructions should use or service this heater.

If you need assistance or heater information such as Instructions Manual, Label, etc., Contact
the manufacturer.

Warning: Fire, burn, inhalation, and explosion hazard. Keep solid combustibles such as

building materials, paper, or cardboard, a safe distance away from the heater as recommended
by the instructions. Never use the heater in spaces which do or may contain volatile or airborne
combustibles, or products such as gasoline, solvent, paint thinner, dust particles or unknown
chemicals.

WARNING: Not for home or recreational vehicle use. No user serviceable parts are
contained in unit. Replace Power Cord only with factory supplied cord.

Other standards govern the use of fuel gases and heat producing products in specific applications.
Your local authority can advise you about these.

Precautions:

1. The RAMFAN INLINE Heater was designed to be used with the UB20 utility blower and the UB20

canister with 4.5m of duct OR with the UB20xx hazardous location blower and UB20xx canister

with 4.5m of duct.

2. The heater will not operate properly if used with other configurations or other blowers.
3. Contact

Customer Service for uses outside of these guidelines.

Setup and Operation:

1. Insert UB20 blower into the Heater air inlet and plug the UB20 into the “Switched Power” receptacle. Ensure

the UB20 blower’s “ON” / “OFF” switch, located on the side of the UB20 is in the “ON” position.

2. Connect the Euramco Safety supplied regulator / hose assembly between the propane tank and the Heater

gas inlet.

3. Attach the UB20 Duct Canister or flexible duct to the Heater air outlet ring and fully extend.
4. Plug the HA01 or HA02 Heater into a 115VAC power source, or the HA03 into a 240VAC power source.
5. Install Optional Thermostat: If the temperature of the space to be heated needs to be regulated install the

optional thermostat and set to highest temperature. Note: The heater does not require the use of a
thermostat to support Heater operation.

6. Open valve on propane tank.
7. Toggle the Heater switch to the “ON” position.
8. After the Heater lights up, adjust the Thermostat Temperature Setting for the desired room temperature. The

red light on the Heater switch will cycle “ON” and “OFF” with the burner flame to regulate the room
temperature.

9. Set the Heater control panel fan switch to the “ON” position if you want the UB20 blower to run continuously

during both thermostat “ON” and “OFF” cycles and after the heater switch has been turned off.

10. Set the Heater control panel fan switch to the “AUTO” position if you want the blower to cycle “ON” and “OFF”

with the demand for heat. When the Heater switch is turned “OFF” the fan will also turn off after the heater
has completed cool down cycle.