3

b) 1/4” DensDeck Prime 12 fasteners per 4’x 8’ board.

c) 1/4" Securock Gypsum-Fiber 12 fasteners per 4’x 8’ board.


2) Wind Speeds to 90 mph.

a) Polyisocyanurate Insulation Board (25 psi Min 1 ½” thick) 16 fasteners per 4’x 8’ board.

b) 1/2” DensDeck Prime 12 fasteners per 4’x 8’ board.

c) 1/2" Securock Gypsum-Fiber 12 fasteners per 4’x 8’ board.


3) Wind Speeds to 100 mph.

a) 7/16” OSB over Flex ISO board. 17 Fasteners per 4’x 8’ board.

b) 5/8” DensDeck Prime 16 fasteners per 4’x 8’ board.

c) 5/8” Securock Gypsum-Fiber 16 fasteners per 4’x 8’ board.


4) Wind Speeds to 120 mph.

a) 7/16” OSB over Flex ISO board. 17 Fasteners per 4’x 8’ board.

b) 5/8” DensDeck Prime 24 fasteners per 4’x 8’board.

c) 5/8” Securock Gypsum-Fiber 24 fasteners per 4’x 8’ board.


Note: Fastener to be Flex Standard Insulation fastener with 3” metal insulation plate. Fastener density
listed above is for field of roof area. Fastener density must be increased a minimum of 60% in the roof
corner areas and 40% in the roof perimeter area.