Flex (sam), 45 & 60 mil thick reinforced tpo sheet – Flex TPO Self Adhered Reinforced Membrane User Manual

Page 3

Advertising
background image

3

membrane. This will help eliminate creases and bubbles that cannot be removed after the sheet is
in place.
3. Roll the Flex (SAM) TPO Membrane with a segmented roller to ensure full contact with the
substrate.
4. Fold back the remaining half of the sheet and repeat the above process.

HEAT WELDING PROCEDURES:

1. Refer to the Flex Adhered Application specification for typical heat welding procedures.
2. The membrane has an uncoated edge on one side along the length of the sheet for membrane
welding. Adjoining membrane sheets are overlapped lengthwise a minimum of 2 in. to provide

for a minimum 1-1/2 in. wide heat weld. It is recommended that all splices be shingled to avoid

bucking of water.
3. An uncoated edge is not provided at the ends of the rolls. Adjoining membrane sheets must be

butted together and overlaid with 6 in. wide Flex Reinforced Membrane, hot air welded along all
edges. Seal all membrane edges (where scrim reinforcement is exposed) with Cut-Edge Sealant.


WALL FLASHING:

1. Walls may be flashed using standard TPO membrane with Flex Bonding Adhesive or with (SAM)

TPO (primer must be utilized on all vertical surfaces).

Contact your Flex Representative for the specific design requirements and installation procedures for this
system.


FLEX
(SAM)

45 & 60 MIL THICK REINFORCED TPO SHEET

BASIC PROPERTIES AND CHARACTERISTICS

Physical Property

Test
Method

Property Of
Unaged Sheet

Property After ASTM
D573 aging

1

28 days @ 240 °F

Nominal thickness with adhesive, in. (mm)
45-mil

(adhesive nominal thickness is 0.010)

60-mil

(adhesive nominal thickness is 0.010)

ASTM D751

0.055 (1.40)
0.070 (1.78)

Thickness over scrim, in. (mm)
45-mil
60-mil

ASTM D6878
Optical Method
(avg. of 3 areas)

typical
0.018 (0.457) ± 10%
0.024 (0.610) ± 10%

Breaking strength, lbf (kN)

ASTM D751
Grab Method

225 (1.0) min.
45-mil
320 (1.4) typical
45-mil
250 (1.1) min.
60-mil
360 (1.6) typical
60-mil

225 (1.0) min. 45-mil
320 (1.4) typical 45-mil
250 (1.1) min. 60-mil
360 (1.6) typical 60-mil

Elongation at break of fabric, %

ASTM D751

25 typical

25 typical

Tearing strength, lbf (N) 8 by 8 in. specimen

ASTM D751
B Tongue Tear

55 (245) min.
130 (578) typical

55 (245) min.
130 (578) typical

Brittleness point, °F (°C)

ASTM D2137

- 40 (- 40) max.
- 50 (- 46) typical

Linear Dimensional Change (shrinkage), %
After 6 hours at 158ºF (70 ºC)

ASTM D1204

+/- 0.5 max.
- 0.2 typical

Ozone resistance, 100 pphm, 168 hours

ASTM D1149

No cracks

No cracks