5. Inspect the welded seams by probing the seams thoroughly with a seam probe. Reweld as necessary.

The completed weld should be a minimum of 1.5” in width.

6. Complete the installation by installing a stainless steel hose clamp and approved caulking at the top of

the vertical flashing.


STORAGE

Store in original unopened containers at temperature range of not less than 40°F to no higher than 105°F.

LIMITATIONS

Caution should be taken in transporting the material so as not to allow physical damage such as abrasion
or punctures.