6 720 607 527

3.7

Troubleshooting

Installation, servicing and repairs may only be carried out by an approved engineer.
The following table illustrates only a few solutions to straightforward problems.

The operations marked with “*” may only be carried out by an approved technician

Fault

Possible Cause

Solution

Appliance does not ignite.

Batteries flat, incorrectly fitted or switch set to
Off

Check position and refit/replace.

Pilot flame lights slowly/with difficulty

Batteries flat.

Replace.

Red LED flashes

Water not hot enough

Check position of water temperature control and
adjust to obtain desired hot water temperature

Water not hot enough, no flame

Gas supply dynamic pressure too low

Check gas cylinder governor and replace if
incompatible or damaged
Check whether gas cylinder (butane) is freezing
when appliance is in operation and re-site in
warmer location if necessary

Flame goes out while appliance is in
operation

Temperature limiter has tripped

Wait 10 minutes then restart appliance. If
problem recurs, call an approved technician.

Flue gas safety device has tripped

Ventilate room. Wait 10 minutes then restart
appliance. If problem recurs, call an approved
technician.

Reduced water flow rate

Inadequate inlet flow rate

Check and adjust.

Dirt in water service cock or mixer unit

Check and clean.

Automatic water valve clogged

Clean filter.*

Heat exchanger clogged (scale)

Clean and descale as necessary.*