TROUBLESHOOTING CHART

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

PART NO. 70 - 290 G375PL (REV-J)

Low

High

Pump

Motor

Reason and remedy

Vacuum Pressure Vacuum Pressure Overheat Overload for problem.

At pump

Filter dirty.

Clean or replace.

At pump

Muffler dirty.

Clean or replace.

At pump

Vacuum line collapsed.

Repair or replace.

Relief valve set too high.

Inspect and adjust.

Relief valve set too low.

Inspect and adjust.

At pump At pump

Plugged vacuum/pressure line.

Inspect and repair.

Vanes sticking.

Clean or replace.

Vanes worn.

Replace.

Shaft seal worn.

Replace.

Dust or offset powder in pump.

Inspect and clean.

Motor not wired correctly.

Check wiring diagram and line voltage.