Gast DOA UL60601-1 User Manual

Page 2

Advertising
background image

Electrical Shock Hazard

This product must be properly grounded.

Do NOT modify the plug provided. If it will not fit the

outlet, have the proper outlet installed by a qualified

electrician.

Check the condition of the power supply wiring.

Do NOT connect this product to wiring that is not in

good condition or is inadequate for the requirements

of this product.

Failure to follow these instructions can result in

death, fire or electrical shock.

Technical Description

Models DOA/DOL are diaphragm type pumps and

operated by single phase, shaded pole AC voltage

motors.

Used in the medical and dental fields, they can be used

as vacuum or pressure - ONLY PUMPING AIR. Under

no circumstances can they be used with any other

gases, fluids or substances mixed with air - particularly

combustible substances.

• Use fitting size 1/4” NPT with tubing.

• Pump is packed in protective packaging for

transportation.

• Pump is provided with hospital grade cord and plug.

Correct installation is your responsibility. Make sure you

have the proper installation conditions and that

installation clearances do not block air flow.

Blocking air flow over the product in any way can cause

the product to overheat.

Mounting

This product can be installed in any orientation.

Mounting the product to a stable, rigid operating surface

and using shock mounts will reduce noise and vibration.

Plumbing

Remove plugs from the inlet and outlet ports. Connect

with pipe and fittings that are the same size or larger

than the productʼs threaded ports. Be sure to connect

the intake and exhaust plumbing to the correct inlet and

outlet ports. Ports will not support the weight of the

plumbing.

Accessories

Filters and mufflers are supplied with some models.

These should be checked periodically and replaced

when necessary. Please consult your Gast

Distributor/Representative for additional filter

recommendations.

Install relief valves and gauges at inlet or outlet, or both,

to monitor performance. Check valves may be required

to prevent back streaming through the pump.

NOTE: Use the proper size tooling for installing the

accessories.

2

RECOGNIZED MEDICAL PUMP

IN ACCORDANCE WITH UL 60601-1

AND CAN/CSA C22.2 NO. 601.1

The pump is not intended for remote, automatic or

unattended use.

It is your responsibility to operate this product at

recommended pressures or vacuum duties and ambient

temperatures. Do not start against a vacuum or

pressure load.

Start Up

If motor fails to start or slows down significantly under

load, shut off and disconnect from power supply. Check

that the voltage is correct for motor or contact Gast

Manufacturing Technical Services.

OPERATION

Injury Hazard

Install proper safety guards as needed.

Use only recommended air handling parts acceptable

and limiting the pressure to 60 PSI, such as relief

valve and pressure gauge.

Product surfaces become very hot during operation,

allow product surfaces to cool before handling.

Do NOT direct air stream at body. Air stream from

product may contain solid or liquid material that can

result in eye or skin damage, wear proper eye

protection.

Do NOT use in flammable or combustible ambient.

Wear hearing protection. Sound level from motor

may exceed 70 dBA.

Failure to follow these instructions can result in

burns, eye injury or other serious injury.

Electrical Connection