General Machine Products 84850 C Pull Finder with Case User Manual

General Machine Products Hardware

Advertising
background image

Underside view of guy

rod and strand gauge

Back
Sight

Front
Sight

Front
Sight

Index

Mark

Screw

Thread

A

C

B

To Measure Pull
To determine the pull at a
corner pole by use of the C
Pull Finder, screw the short
arm A into the corner pole,
as illustrated in figure 2.
Adjust arm C so that the line
of sight, when sighting over
the back sight and the front
sight on arm C, is tangent to
the surface of the pole adja-
cent to the corner. In a simi-
lar manner, line up arm B,
sighting on the other pole
adjacent to the corner.
Check arm C to make cer-
tain it has not moved. The
pointer on arm B now indi-
cates, on the scale on arm
C, the pull in feet at the
corner.

A

B

C

Figure 2

Figure 1

General Machine Products, Co., Inc.

3111 Old Lincoln Hwy, Trevose, PA 19053
tel: 215-357-5500 www.gmptools.com

Over for Bisecting Angle instructions

C Pull Finder P/N 84850

p/n 27936 ver 1 AK