4

The following list shows the various sizes, types
and designations of messenger cables for which
the tools can be calibrated:

To obtain an accurate measurement it is imperative
that the strand to be measured be positively identi-
fied as to its actual diameter and its grade, either
Utilities Grade or Extra-High Strength. Secondly,
the Strand Tensionmeter to be used must have a
current calibration chart with a corresponding se-
rial number which has a calibration for the specific
strand you have identified.

The Tensionmeter measures the force required to
deflect the strand to an out-of-line position and
registers the amount of force required on the inte-
gral dial. The actual strand tension is then deter-
mined by referring to the calibration chart specifi-
cally prepared for and furnished with each Ten-
sionmeter, which converts the dial indicator read-
ing into the actual tension value.

The instrument measures tension in pounds force
to within an accuracy of three percent (± 3%) or ±
150 pounds, whichever is greater.

Inches

mm

Designation

Description

1/4

6.35

6.6M

1 X 7 EHS

5/16

7.94

6M

1 X 7 Utility Grade

5/16

7.94

10M

1 X 7 EHS

3/8

9.52

10M

1 X 7 Utility Grade

7/16

11.11

16M

1 X 7 EHS

7/16

11.11

16M

1 X 7 Utility Grade

Nominal Diameter

Advertising