GreenGuard DC14 Drainage Mat User Manual

Page 3

Advertising
background image

G R E E N G U A R D

®

D C 1 4 I N S T A L L A T I O N G U I D E F O R C O M M E R C I A L A N D R E S I D E N T I A L C O N S T R U C T I O N

2

1-800-241-4402 www.TrustGreenGuard.com

TABLE OF CONTENTS

1.0 GENERAL INFORMATION

2

2.0 INDUSTRY STANDARDS/CODE COMPLIANCE REQUIREMENTS

2

3.0 PRODUCT DESCRIPTIONS

2

4.0

FASTENERS AND FASTENING OPTIONS

2

5.0

FLASHINGS AND JOINT/SEAM SEALING PRODUCTS

3

6.0 INSTALLATION OF WATER-RESISTIVE BARRIER/GREENGUARD BUILDING WRAPS

3-4

7.0 INSTALLATION OF GREENGUARD

®

DC14 DRAINAGE MAT

5-6

8.0

INSTALLATION OF GREENGUARD

®

DC14 IN RESIDING APPLICATIONS

6

9.0 INSTALLATION OF GREENGUARD

®

DC14 AS THE WATER-RESISTIVE BARRIER IN RESIDING APPLICATIONS

6-7

10.0 REPAIRING DAMAGED BUILDING WRAP AND DRAINAGE MAT

7

11.0 USAGE AND LIMITATIONS

8

12.0 WARRANTY AND CONTACT INFORMATION

8

1.0 GENERAL INFORMATION

This Guide describes the GreenGuard

®

DC14 Drainage Mat and

its intended use in commercial and residential construction

applications where it is installed in wall systems in combination

with various types of exterior wall sheathings, water-resistive

barriers and exterior coverings such as brick, stone, exterior

insulation finish systems (EIFS), conventional stucco, vinyl, fiber

cement, wood, etc.

This Guide is intended to provide installation guidelines for the

use of GreenGuard

®

DC14 Drainage Mat. These guidelines

are not intended to address all possible combinations of

construction materials that may be used in a wall system. For

this reason, the installation information provided is intended

only as a guide and is for the convenience of contractors,

specifiers and other interested parties.

2.0 INDUSTRY STANDARDS/CODE COMPLIANCE

REQUIREMENTS

GreenGuard

®

DC14 Drainage Mat meets the requirements of

the 2006, 2009 and 2012 International Building, Residential

and Energy Codes (IBC, IRC and IECC). These codes require

that foam plastic insulation materials meet specific flame

spread and smoke developed ratings. Applications involving

the use of cementitious exterior coverings, such as exterior

insulation finish systems (EIFS), conventional stucco and

adhered thin masonry veneers (brick/stone), require the use

of two layers of Grade D building paper or equivalent. This

requirement can be met by using one layer of a water-resistive

barrier (building wrap) and one layer of GreenGuard

®

DC14

Drainage Mat.

• International Code Council, Evaluation Services, Inc. (ICC-

ES) - GreenGuard

®

DC14 Drainage Mat (see ESR-2136). The

product is a recognized water-resistive barrier.

• National Building Code of Canada, GreenGuard

®

Fanfold

Underlayments (Evaluation Report 12764-R)

3.0 PRODUCT DESCRIPTIONS

GreenGuard

®

DC14 Drainage Mat – This product is an extruded

polystyrene insulation board product designed with contoured

channels that allow for enhanced drainage performance. The

product meets the requirements of “ICC-ES Acceptance Criteria

for Foam Plastic Insulation” (AC12) and “ICC-ES Acceptance

Criteria for Foam Plastic Panels Used as Water-resistive

Barriers” (AC71).

4.0 FASTENERS AND FASTENING OPTIONS

GreenGuard

®

DC14 Drainage Mat is mechanically attached

either through structural sheathing board or insulation board

to underlying framing members or attached directly to framing

members. The following chart shows the fastening information

for various framing and wall types:

GreenGuard

®

DC14 Drainage Mat

Minimum Required

Metal

Wood

Masonry

Roofing Nail or Screw Type:

Corrosion-resistant

(Example: galvanized,

hot dipped)

1

5

/

8

in.

1

5

/

8

in.

1

3

/

4

in.

Tap Con

GreenGuard Caps or

Metal/Plastic Washers,

(Min. diameter)

1

3

/

4

in

1

3

/

4

in

1

3

/

4

in

Max. Fastener Spacing

(inches)

24

24

24

Note: When attaching wall ties for anchoring masonry exterior

claddings, first install a patch of GreenGuard

®

Flashing at the

penetration site before installing the wall tie. The patch should

be of a size to seal only the penetration points.

Advertising