GreenGuard Fanfold Siding Underlayment User Manual

Greenguard, Fanfold underlayment installation guide

Advertising
background image

GreenGuard

®

Fanfold Underlayment Installation Guide

1-800-241-4402 www.TrustGreenGuard.com

Care should be taken when installing GreenGuard

®

Fanfold Underlayment under siding

materials. These products must be adequately fastened so that the entire board lays

completely flat against the existing siding material or sheathing. Avoid overdriving fasteners,

since this will crush the insulation, resulting in a wavy appearance of the finished exterior

wall. Additional R-value (a system R-value) can be obtained when using GreenGuard Reflective

Siding Underlayments (EPS and XPS) by either installing them with the reflective surface next

to lapped siding having uniform air spaces at each lap or by installing 1/2 inch thick wood

furring strips spaced 2 feet apart and attaching the underlayment with the reflective surface

next to the furring strips to create a reflective air space.

Verify that substrate is flat, dry, and free of foreign material that will damage the GreenGuard

®

Fanfold

Underlayment. Beginning of installation means installer accepts the existing conditions.

For the most current product and code compliance information, go to www.TrustGreenGuard.com

Warning:

Foam plastic insulation will ignite if exposed to fire of sufficient heat and intensity. Protect foam insulation from

exposure to open flame or other ignition sources during shipment, storage, and installation.

Storage and Handling:

When stored outdoors, all materials should be protected from exposure to direct sunlight using an

opaque light-colored tarp or the original packaging. Material that has been unwrapped should be carefully rewrapped.

Pactiv Building Products believes the information and recommendations herein to be accurate and reliable. However, since

use conditions are not within its control, Pactiv does not guarantee results from use of such products or other information

herein and disclaims all liability from any resulting damage or loss. NO WARRANTY, EXPRESS OR IMPLIED, IS GIVEN AS

TO THE MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, OR OTHERWISE WITH RESPECT TO THE PRODUCTS

REFERRED TO.

Install GreenGuard

®

Fanfold Underlayments directly over old siding using galvanized or alu-

minum roofing nails, with nails spaced about 2 feet apart. If the existing siding is damaged,

remove it and install GreenGuard

®

Fanfold Underlayment directly to the substrate.

Install the new siding material over GreenGuard

®

Fanfold Underlayment in accordance with the

siding manufacturer’s installation instructions.

A.

C.

B.

GreenGuard

®

is a registered trademark of Pactiv LLC.

©2014 Pactiv LLC.