Modulated

Amplifier

Logic Functions

Used with (Input)

Full Description

Module

Model

NONE (ON/OFF)

4-input logic gate:

AND, NOR, X-NOR

Latch or alternate-action

flip-flop

NONE (ON/OFF)

Banner high-performance

remote sensors

Banner SP100FF modu-

lated fixed-field sensor

ONE-SHOT

MICRO-AMP logic
modules are designed to
accept the output signal
from a MICRO-AMP
amplifier and process
that signal for a required
logic function. MICRO-
AMP logic modules
themselves contain no
amplifier.

YES

ON-delay or OFF-delay

NONE (ON/OFF)

Banner SP100 Series min-

iature modulated remote

sensors

Banner catalog or

data sheet 03523

Banner catalog or

data sheet 03341

MA3A

MA3-4 and MA3-4P

MA4-2

MA4G

MA4L

MA5

MPC3

(for printed circuit

board mounting)

YES

YES

Banner catalog or

data sheet 03350

Banner catalog or

data sheet 03351

Banner catalog or

data sheet 03352

Banner catalog or

data sheet 03353

Banner catalog or

data sheet 03336

Other MICRO-AMP

®

Modules

Switches, contacts, or
NPN (current sinking)
output of dc sensors or
amplifiers, including:
Banner MULTI-BEAM,
MAXI-BEAM, VALU-
BEAM, MINI-BEAM,
and ECONO-BEAM
sensors; plus MAXI-
AMP and MICRO-AMP
modules.

The MPS-15 Series power supplies are designed specifically to supply power for the

Banner MICRO-AMP series amplifiers and logic modules. They are constructed on small

PC boards that are track-mountable for compatibility with other track-mounted MICRO-

AMP components. The MPS-15 includes a socket for a MICRO-AMP amplifier or logic

module having current sinking (NPN) output*. The combination of an MPS-15 series

power supply and a MICRO-AMP module makes a complete and compact sensing and/or

control system.
A built-in 5-amp rated SPDT output relay is supplied for easy interfacing to an external

load or circuit. Its action is controlled by the outputs of a MICRO-AMP module which is

plugged into the on-board module socket*. A switch on the PC board selects which module

output (normally open or normally closed) will activate the relay.
Two models are available. Model MPS-15 is for 120V ac operation. Model MPS-15-230

is for 220/240V ac power. Up to three MICRO-AMP modules may be powered by one

MPS -15 or MPS-15-230 power supply. A 4-inch (10cm) long mounting track is included

with each supply. Optional 6-inch (15cm) track model TR100-6 neatly accomodates the

MPS-15 Series PC board plus the PC boards of two additional RS8 sockets to form a

complete three-module MICRO-AMP sensing/logic system. (See Mounting Track infor-

mation, page 3.)

*Do not plug MICRO-AMP modules with PNP (current sourcing) outputs ("P" suffix) into the socket on the MPS-15 or MPS 15-230 power supply.

MPS-15 and MPS-15-230 Power Supplies

WARNING

MICRO-AMP

®

Systems do NOT include the self-checking redundant circuitry necessary to allow their use in

personnel safety applications. A sensor or amplifier failure or malfunction can result in either an energized or a de-energized output

condition.

Never use this product as a sensing device for personnel protection. Its use as a safety device may create an unsafe condition which

could lead to serious injury or death.

Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and

ANSI machine safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and

they must NOT be used as sensing devices for personnel protection.

Advertising