System error, Others – Bell & Howell S02294A User Manual

Page 28

Advertising
background image

Image Scanner User's Manual

- 20 -

¡

Others

If a problem occurs that is not indicated by the indicators, follow the directions below.

Cause

Power cord is not plugged in.

Power switch is not turned on.

I/F cable is not connected securely.

Host computer malfunction.

SCSI ID is not correct.

DIP switches setting is not cor-

rect.

The roller is not clean.

Specifications of originals do not

match with the document condi-

tions.

The contact glass is not clean.

The roller is not clean.

Problem

Power does not

go on.

Does not run af-

ter power is on.

Originals are not

fed normally.

Scanned image

is abnormal.

Corrective action

Plug the power cord in.

Turn on the power.

Connect it securely.

Reset the computer.

Correct the SCSI ID.

Correct the DIP switches

setting.

Clean the roller.

Place originals which

match the document con-

ditions.

Clean the contact glass.

Clean the roller.

Refer

P.7

P.8

P.6

-

P.7

P.8

P.15

P.12

P.14

P.15

¡

System error

Scanner

Document feeder

Green

Amber

Green Amber

Blinking Blinking Blinking Blinking

Corrective action

Initialize the scanner by switching the scanner off and on again or press the reset switch.

If the error is not solved, please contact your service representative.