HYDAC AS 1000 User Manual

Page 9

Advertising
background image

User Manual AS 1000

09.04.2008

9

10. Displays

10.1 HDA 5500

The HDA 5500, version HDA 5500-1-1-AC-000 or HDA 5500-1-1-
DC-000, is a display unit with 4 programmable switch outputs,
specially designed for use with the AS 1000.
In conjunction with the HDA 5500 it is possible to display the
actual measured values.

Order no.: 908869 HDA 5500-1-1-AC-000
Order
no.: 908870 HDA 5500-1-1-DC-000

Connection to a HDA 5500
X1:

Pin 1: + supply HDA 5500

X1:

Pin 2: - supply HDA 5500


X2:

Pin 5: GND AS 1000

(blue)

X2:

Pin 6: +12V supply AS 1000

(brown)

X2: Pin

4:

temperature

(black)

X2:

Pin 2: saturation point

(white)



10.2 HMG 510

Portable 2-channel data recorder, specially designed to display measured values from HSI-
and SMART sensors.

In conjunction with the HMG 510 it is possible to display the actual measured values on the
display of the HMG 510.

Order no.: 909889 HMG 510-000

Connection to a HMG 510
Remove the supply cable from the electrical connection of the AS 1000 and screw the
connection adaptor AS / HLB "ZBE 36" into the sensor. Connect one of the inputs A or B of
the HMG 510 to the output of the "ZBE 36" using a sensor cable "ZBE 30-0x"

Advertising