SAE classes acc. to AS 4059

The following SAE values can be output via the analog output:

SAE A-D (

SAEMAX

)

Only a single value is output.

SAE A / B / C / D

All values are sequentially time-coded before output.

SAE A / SAE B / SAE C / SAE D

Only one value is output.

SAE+T

All values are sequentially time-coded before output.

HDA.SAE

All values are sequentially time-coded before output.
Primarily this signal was planned for the HDA 5500 (HYDAC digital display Unit),
however, this can use in other applications.

The I=4.8 - 19.2 mA or voltage U=2.4 - 9.6 V DC current range depends on the
contamination class according to SAE=0.0 - 14.0 (resolution 0.1 class).

Current I

SAE class / error

Voltage U

I <4.00 mA

Cable break

U <2.00 V

4.0 mA < I < 4.1 mA

Device error, device not ready

2.00 V < U < 2.05 V

4.1 mA < I < 4.3 mA

Not defined

2.05 V < U < 2.15 V

4.3 mA < I < 4.5 mA

Flow error (flow too low)

2.15 V < U < 2.25 V

4.5 mA < I < 4.8 mA

Not defined

2.25 V < U < 2.40 V

I = 4.80 mA

SAE 0

U = 2.4 V

I = 4.90 mA

SAE 0.1

U = 2.45 V

I = 5.01 mA

SAE 0.2

U = 2.51 V

...

...

...

I = 5.83 mA

SAE 1

U = 2.92 V

I = 6.86 mA

SAE 2

U = 3.43 V

I = 7.89 mA

SAE 3

U = 3.95 V

I = 8.91 mA

SAE 4

U = 4.46 V

I = 9.94 mA

SAE 5

U = 4.97 V

I = 10.97 mA

SAE 6

U = 5.49 V

I = 12.00 mA

SAE 7

U = 6.00 V

I = 13.03 mA

SAE 8

U = 6.52 V

I = 14.06 mA

SAE 9

U = 7.03 V

I = 15.09 mA

SAE 10

U = 7.55 V

I = 16.11 mA

SAE 11

U = 8.06 V

I = 17.14 mA

SAE 12

U = 8.57 V

I = 18.17 mA

SAE 13

U = 9.09 V

...

...

...

I = 18.99 mA

SAE 13.8

U = 9.50 V

I = 19.10 mA

SAE 13.9

U = 9.55 V

I = 19.20 mA

SAE 14.0

U = 9.60 V