Bunn Trifecta 428220001E User Manual

Page 16

Advertising
background image

Page 16

Amount of press out time during primary rinse mode.

DEFAULT: 60

Range: OFF/ 1-60

2nd RINSE AIR ON

60 Secs

Primary rinse mode. "OFF" is equal to push & hold. Num-

bers represent seconds it will continue to rinse when

button is released.

DEFAULT: 2.0

Range: OFF/ 1-4.0

2nd RINSE TIME

2.0 Secs

11.

12.

Total brew counter (Can not be reset)

Brew counter (Can be reset)

BrewCount 1500

BrewCount 1500

RESET

NEXT

NEXT

Adjust force of "PRESS OUT"

DEFAULT: 7

Range: OFF/1-7

RINSE AIR POWER

-

+

- - - - - - - 7

-

+

-

+

13.

14.

15.

16.

Press "YES" if you would like to program a phone number

for a factory authorized service department that will be

displayed if the brewer should encounter a fault code.

ENTER SERVICE #

NO

YES

_

Use the UP/DOWN buttons to scroll through numeric digit

for that position. Use the button to move curser to the

next digit to the right. Press the to move curser to the

left. Once you are finished programming the number, scroll

all the way to the right to advance to next screen.

42822.1 072810

A

ADVANCED ADJUSTMENTS & OPTIONAL SETTINGS

Advertising