New Buck Corporation 21 User Manual

Page 25

Advertising
background image

1. Sluggish Heater

1. Obstruction in Chimney

2. Manual damper in

chimney is closed



3. Wet or unseasoned

wood being burned

4. Poor chimney draft

1. Check for and remove

obstruction

2. Open manual damper

and wire shut with
stainless steel wire or
remove damper

3. Burn dry seasoned wood

4. Improper chimney height

or wrong size flue is
being used. Cooler
temperatures caused by
external chimney.

2. High fuel consumption












3. Backpuffing



4. Smoke rollout when

heater door is opened


1. (a) Close inlet air control

as much as possible to
maintain desired heat
output.
(b) Check gaskets,
reinstall fiberglass
gasketing around doors
and glass as necessary

2. Check door gasket,

check adjustment of door
latch


1. Chimney may need

wind diverter. Raise
chimney for better draft.


1. Chimney may need

wind diverter. Raise
chimney for better draft.


2. Crack door for 15

seconds before fully
opening door.


1. Improper regulation of

draft or inlet air








2. Improper door fitting



1. Gusts of Wind



1. Wind gusts blowing down

the chimney



2. Opening heater door too

fast

SECTION VIII

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

23

Advertising