3 mounting, 5 permissible pressure at the sheath – JUMO 60.3031 Surface-mounting thermostats, ATH.-SE Operating Manual User Manual

Page 12

Advertising
background image

3 Mounting

12

3.5

Permissible pressure at the sheath

3.5.1

Sheaths 20 and 30

3.5.1.1

Stainless steel sheath

Material

l

Permitted flow
velocities

on request

3.5.1.2

Sheath "20" made of brass

Emitted flow
velocities

on request

A

The following values refer to the maximum pressure of the probe mounting
concerned. The maximum pressure which can be sealed depends on the
mounting conditions and may possibly be lower.

Tube and nipple material: X 6 CrNiMoTl 17 122

Temperature

Tube diameter

8 x 0.75 mm or conical

10 x 0.75 mm

Max. permissible pressure

Max. permissible pressure

100 °C

92 bar

74 bar

150 °C

88 bar

71 bar

200 °C

83 bar

67 bar

300 °C

72 bar

58 bar

Sheath "20" tube and nipple material: brass

Temperature

Tube diameter

8 x 0.75 mm

10 x 0.75 mm

Max. permissible pressure

Max. permissible pressure

100 °C

50 bar

40 bar

150 °C

48 bar

39 bar

H

The plain cylindrical probe, Form 10 must only be used in pressureless
medium.

A

Due to the general accuracy of response, the instrument must only be used
with the factory-supplied sheaths.