JUMO 60.8425 Contact dial thermometer Data Sheet User Manual

Contact dial thermometers, Technical data, Particularities

Advertising
background image

Page 1/6

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Type 608425/2316

2011-11-08/00402234

Contact Dial Thermometers

Type 608425

Data Sheet 608425

Type 608425/2496

Technical data

Type 608425

round panel- or surface-mounting housing

Typ 608425

square panel-mounting instrument

Housing

housing with bayonet lock

in stainless steel (1.4301)

galvanized sheet steel housing, fixed at back by a

bracket; front bezel in stainless steel (1.4301)

Enclosure protection

IP65 as per EN 60 529

front: IP51 as per EN 60 529

back: IP00 as per EN 60 529

Electrical connection

terminal box: conductor cross-section up to

2.5mm

2

cable gland suitable for cable dia. 6.5 — 13 mm

screw terminals: conductor cross-section up to

2.5mm

2

Glass window

polycarbonate

plexiglas (PMMA)

Scale

white, black lettering

Accuracy class

Class 1 to EN 13190

Anti-kink spring

for capillary instruments, at the housing and probe

Setpoint adjustment

through setpoint adjuster on the glass window

Indication correction

at the back, no indication correction for styles 01 and 20 (100 mm dia.)

Temperature limits

for transport and storage -20°C to +70°C (with a 0 to +60°C range: max. 65°C)

Operating position (NL)

unrestricted

Liquid filling

Gas filling

Measuring system

range (AB)

≤ 350°C

range (AB)

≤ 400°C

Time constant
t

0.632

approx. 12 sec, measured in water bath,

with a 6 mm dia. copper probe

approx. 4 sec, measured in oil bath,

with a 10 mm dia. stainless steel probe

Ambient temperature
error

in % of indication range (referred to the deviation from the reference value at +23°C)

at housing

0.15% of indication range

per °C change of ambient temperature

0.05% of indication range

per °C change of ambient temperature

on capillary (per meter)

0.03% of indication range

per °C change of ambient temperature

no effect

At higher ambient temperatures – higher temperature indication – lower switching point

Particularities

• temperature controller with indication for panel or surface mounting

• Class 1

• protection up to IP65

• housing sizes: 100 mm and 160 mm diameter, bezel 96 x 96 mm

Brief description

Contact dial thermometers are universally applicable instruments with indication of the actual
value, for temperature measurement, control and monitoring.
The temperature-dependent change in volume of a liquid-filled measuring system (or the
temperature-dependent change of pressure in a gas-filled measuring system) is converted into
a rotary movement of the pointer by a Bourdon tube, without any intermediate gearing. The
rotary movement of the pointer shaft is used to operate the switched output.
The pointer is directly linked to the measuring system, which makes the overall system
extremely torsionally rigid. Vibrations are transmitted to the pointer only to a minor extent.
The switched output can be implemented as a slow-break, magnetic snap-action or inductive
contact. The slow-break or magnetic snap-action contact is an auxiliary circuit switch that,
depending on the direction of movement, opens or closes an electrical circuit at the set limits,
by means of a contact arm that is attached to the moving pointer.
The inductive contact is an electronic limit detector operated by a contactless position sensor