JUMO 707020 dTRANS T02 - Four-Wire Transmitter Data Sheet User Manual

Page 7

Advertising
background image

2014-08-08/00379095

Data Sheet 707020

JUMO GmbH & Co. KG • 36035 Fulda, Germany

Page 7/12

Customized linearization

Electrical data

Version 707025/... (Ex)

Interpolation: linear

max. 41 calibration points

Interpolation: square-law

max. 53 calibration points

Interpolation: cube-law

max. 61 calibration points

Input of calibration points

through setup program (accessory)

Supply voltage

- types 707021/... and 707022/...

20 — 53V AC/DC, 48 — 63Hz or

110 — 240V AC +10/-15%, 48 — 63Hz

- type 707025/...

230V AC ±10%, 48 — 63Hz or

20 — 53V AC/DC, 48 — 63Hz

Power consumption

max. 5VA

Test voltage

to DIN 61010, Part 1

- between input or output and

supply
- with AC supply
- with AC/DC supply

2.3kV/50Hz, 1min

510V/50Hz, 1min

- between input and output

510V/50Hz, 1min

Isolation
- between input and output
- between input and mains supply
- between output and mains supply
- between output and setup plug

50V

250V
250V

no isolation between output and setup plug

Marking

Ambient temperature range

-10 to +60°C

Supply circuit
(terminals L1(L+), N(L-) and PE)
Max. safe voltage

230V AC ±10%, 48 — 63Hz or

20 — 53V AC/DC, 48 — 63Hz

U

m

= 253V

Output circuit
(terminals 9(+) and 10(-))
Max. safe voltage

0 — 20mA

U

m

= 253V

Output circuit
(terminals 11(-) and 12(+))
Max. safe voltage

0 — 10V

U

m

= 253V

Setup circuit
Max. safe voltage

5V TTL level

U

m

= 253V

Sensor circuit
(terminals 1 through 5)
type of protection Intrinsic Safety
Ex ia IIC or Ex ia IIIC
Maximum values:

U

0

= 6.0V

I

0

= 18.9mA

P

0

= 28.4mW

linear characteristic

L

i

negligibly low

C

i

negligibly low

For relationship between explosion
group and the external reactances
reference is made to the table:

II (1) G [Ex ia Ga] IIC

II (1) D [Ex ia Da] IIIC

[Ex ia Da] IIIC

[Ex ia Ga] IIC

IIC

IIB

IIA

L

o

20 mH

20 mH

20 mH

C

o

1.3 µF

7.1 µF

10 µF