Order details – JUMO 902520 Indoor and Outdoor RTD Temperature Probe Data Sheet User Manual

Page 5

Advertising
background image

2011-05-20/00311507

Data sheet 90.2520 (90.2523)

Page 5/7

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany
Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

e-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

e-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

e-mail:

[email protected]

Internet: www.jumo.us

Order details:

Indoor and outdoor RTD temperature probe

(1) Basic type

902520/10

Indoor RTD temperature probe
Protection class IP20

902520/11

Indoor and outdoor RTD temperature probe
Protection class IP54

902520/12

Indoor and outdoor RTD temperature probe
Protection class IP65

902520/13

Indoor and outdoor RTD temperature probe
with stepped sheath
Protection class IP65

902520/15

Outdoor RTD temperature probe
Protection class IP65

(2) Operating temperature in °C

x

361

-50 ... +90 °C

x x

568

-30 ... +60 °C (measuring range only in connection with extra code 330 or 333)

x

x x

572

-30 ... +80 °C (standard)

x

635

-20 ... +80 °C (standard)

x

x x

803

0 ... 40 °C (measuring range only in connection with extra code 330 or 333)

x

x x

807

0 ... 60 °C (measuring range only in connection with extra code 330 or 333)

(3) Measuring insert

x

x

1001

1x Pt 100 in 3-wire-circuit

x x x x x

1003

1x Pt 100 in 2-wire circuit

x x x x x

1005

1x Pt1000 in 2-wire circuit

x x

x x

1009

1x Ni1000 in 2-wire circuit

x

1619

1x KTY 81-110

x

1728

1x NTC 1 kOhm

x

2001

2x Pt100 in 3-wire-circuit

x x x

2003

2x Pt100 in 2-wire circuit

(4) Tolerance class as per DIN EN 60 751

x

0

Technical data Ni/NTC/KTY

x x x x x

1

Class B (standard)

x

x x

2

Class A (not for basic type 902520/10 in connection with transmitter)

x

x x

3

Class AA (1/3 DIN B) (not for basic type 902520/10 in connection with transmitter)

(5) Extra codes

x x x x x

000

None

x

x x

330

Transmitter analog, output 4 ... 20 mA

2

(in connection with 1x Pt100)

x

x x

333

Transmitter analog, output 0 ... 10 V

2

(in connection with 1x Pt100)

x

903

Cable screw-connection (IP65)

(1)

(2)

(3)

(4)

(5)

Order code

-

-

-

/

,...

1

Order example

902520/10

-

572

-

1001

-

1

/

000

1

List extra codes in sequence, separated by commas.