7 Configuration

7.1 Analog inputs „INPUT“

Depending on the instrument version, up to two
analog inputs are available.

Configuration

Analog inputs
Limit
comparators
Outputs
Binary
functions
Display /
Operation
Interfaces

INPUT1 (analog input 1)
INPUT2 (analog input 2)

Parameter

Value/

Selection

Description

Sensor type

SENSOR

0
1
2
3
4
5
7
8
9

10
11

No function
RTD temperature probe in 3-wire circuit
RTD temperature probe in 2-wire circuit
RTD temperature probe in 4-wire circuit
Thermocouple
Resistance transmitter
0…20mA
4 ... 20mA
0…10V
2…10V
0 ... 1V

Factory set on analog input 2: no function