Piston pump, Piston pump -3 – Kinze 3700 Front Folding Planter Rev. 7/14 User Manual

Page 165

Advertising
background image

TM

Model 3700

M0233-01

Rev. 10/11

6-3

Troubleshooting

piSTOn pUMp

prObLeM

pOSSibLe CaUSe

SOLUTiOn

Pump hard or impossible to

prime.

Valves fouled or in wrong place.

Inspect and clean valves.

Air leak in suction line.

Repair leak.

Pump set too low.

Adjust pump setting.

Packing washers worn out.

Replace.

Low metering.

Valves fouled or in wrong place.

Inspect and clean valves.

Air leak in suction line.

Repair leak.

Pump set too low.

Adjust pump setting.

Broken valve spring.

Replace spring.

Over meters.

Broken discharge valve spring.

Replace spring.

Trash under valves.

Inspect and clean valves.

Improper rate setting.

Adjust pump setting.

Leaks through when stopped.

Broken discharge valve spring.

Replace spring.

Trash under valves.

Inspect and clean valves.

Fertilizer solution leaking

under stuffing box.

Packing washers worn out.

Replace.

Pump using excessive oil.

Oil seals or O-ring worn and leaking.

Replace.

Pump operates noisily.

Crankcase components worn

excessively.

Inspect and replace if necessary.

Advertising