Muxbus, Isobus m0246, 35 muxbus – Kinze ISOBUS Electronics Package (3000 Series) Rev. 5/14 User Manual

Page 41: Settings, Jumpstar t sensor

Advertising
background image

Drop Down List

TM

ISOBUS

M0246

Rev. 5/14

35

MUXBUS

In the Muxbus settings screen, the sensors can be programmed, a new sensor can be added or removed, and the status
of each sensor can be viewed.

Programming Sensors
1.

With all of the sensors unplugged from the main harness, select Auto Detect.

2.

A list will appear on screen that will instruct when and how to plug in different sensor types.

The list can also be viewed by selecting the drop down list in the center of the screen.

IMPORTANT: Sensors must be programmed in exact order. Follow instructions on screen.

3.

Each time a sensor is plugged in, the display will beep.

4.

In the center of the screen, there will be a count of how many sensors are left to program.

5.

Once all sensors are plugged in, the status screen will reappear.

Replacing a Sensor
1.

Remove the sensor that is being replaced.

2.

Select that sensor from the drop down list in the center of the page.

3.

Touch REMOVE from the right side of the screen.

4.

Plug in the new sensor.

5.

Select that sensor from the drop down list in the center of the page.

6.

Select ADD from the right side of the screen.

diagnostics
In the upper portion of the screen, the status of each port is displayed as well as the communication rate. Port 1 is
Mux A and Port 2 is Mux B.

The status of each sensor can also be seen by selecting the sensor from the drop down list in the center of the
screen. The status will then be displayed below, along with the serial number, the port it is plugged into, type of
sensor, sensor ID, and communication rate.

Prev

Por t 1:

OK Low

Por t 2:

OK Low

Jumpstar t Sensor

Status:

S/N:

Por t:

Type:

ID:

Max. Rate:

Unassigned
0
1
0
0
Low

Status Rate

3:00 PM

ON

F

E

J

AUTOSWATH

25

DOWNFORCE

DEPTH

10

Prev

CROP TYPE

CORN

POPULATION

MUXBUS SENSORS TC

Settings

Advertising