SCREEN FUNCTIONS

A.

Length Indicator: Displays length of cable being measured. Blinking

dashes mean the cable length or total capacitance has exceeded the

maximum limits of the unit. When using a preset value, this will update

every 5 seconds. When in “User” Mode, this will update every 1 second.

B.

Active Cable Preset Icon: Displays the selected preset cable

value or “User” Mode.

C.

Ready Icon: When lit, indicates that the unit is ready to take a length

measurement.

D.

Short Icon: Indicates whether the cable being tested has a short.

E.

Unit of Measurement: Indicates the unit of measurement (feet or

meters) currently being used to display the measurement. To switch

between metric and imperial units, hold the UP and DOWN arrow

keys for one second.

F.

Voltage Icon: When lit, indicates that a voltage is present in the cable

being tested. The unit is disabled when this icon is lit. Immediately

disconnect the unit from the cable and disconnect the cable from the

voltage source. NOTE: The absence of the “Voltage!” symbol DOES

NOT necessarily mean that there are 0 volts on the line.

G.

Capacitance per unit length constant: In “User” Mode, the pF

constant will be displayed. Use the UP or DOWN arrow keys to adjust

this value.

H.

Battery Indicator: This will fl ash when the battery drops below 6V.

Replace the battery at this point.

KEYPAD

UP/DOWN

• Use these buttons to cycle through cable presets and

“User” Mode.

• In “User” Mode, use these buttons to adjust the

capacitance per unit length constant

SEL

• In a testing mode (preset or user) press this to exit and

select a new mode.

• When a new mode is chosen, press again to re-enter

testing mode.

POWER

• Short press to turn the unit on or off.