ERM-3K3U System Diagram

Reservoir

Radiator

(Primary Heat Exchanger)

Radiator -

The primary heat exchanger is the main cooling element, and provides

high thermal dissipation in a relatively small area. Inside, louver fins are webbed
between flat horizontal liquid pipes.

Reservoir & Pump -

The coolant tank is transparent for easy liquid-level monitoring

through the front window. It is filled through a small metal fill port on top. The white
reservoir LED illumination can be toggled via the front button.

Pump

Liquid Outlet
Liquid Inlet

DC Signal and Sensors

Reservoir Illumination Button

AC Power Plug

Power
Button

System Features

Display Panel

CAUTION:

This cooling system allows full user control of hardware

safety settings, such as audio alarm, shutdown, and pump speed.
Please be sure to configure your Display Panel properly, or damage
to your computer, data, and/or equipment could result.

!

The Koolance display panel allows control and
monitoring of various aspects of the cooling
unit. 4 buttons are used, with directional
arrows to navigate or change settings, and a
center button to enter/exit.

• On the main screen, hold

for 3 seconds to change display units between

ºC/ºF and LPM/GPM.
• You can exit any menu and return to the main screen by holding

for 2

seconds.
• To reset ALL settings to default, hold ▼ + ▲ for 5 seconds.

Main Menu

To enter the main menu, briefly press

. The selected option will begin flashing.

Use ▼ and ▲ to navigate this menu.

TEMP SET: Temperature, alarm, and shutdown settings
FAN SET: Fan settings
PUMP SET: Pump settings
FLOW SET: Flow meter settings
DISPLAY SET: Display settings

When in the top menu, press

to enter one of the above categories. To exit from

here, press ◄.

TEMP SET

The temperature menu allows configuration of the alarm and safety shutdown
options. This cooling

system can monitor up to 3 (included) temperature sensors.

An audio alarm will sound if any sensor reaches its set alarm point. The offending
sensor will also flash in the display, and the radiator fans and pump will increase

Navigate Up,

Increase Setting

Navigate Down,

Decrease Setting

Navigate

Left

Navigate

Right

Enter/Exit

NOTE:

After powering on this unit, wait

5 seconds before powering it off again.
Otherwise, the display may lock-up
and require reset (hold ▼ + ▲ for 5
seconds.)