5

User Manual

LED Display Panel

Temperature Sensors

Exos-2 systems can monitor up to 3 temperature sensors (included). The fi rst
LED digit indicates which sensor channel is currently displayed in the temperature
reading. To cycle through sensors, press SET.

Fan Speed

This option adjusts the radiator fan speed. Higher speeds can improve performance,
but will produce more noise. There are 1 automatic and 10 manual fan settings
(1-10). Press the

▲ or ▼ buttons to cycle through these settings, or hold down

an arrow to skip to the highest or lowest mode directly.

Automatic mode will adjust the fans for you based on temperature values from
sensor #1. This mode is reached by lowering the fan setting to “0” (Aut / A1 will
be displayed). Details on fan modes are as follows:

CAUTION: Exos-2 systems allow full user control of hardware safety
settings, such as audio alarm and shutdown. Please be sure to con-
fi gure your LED Display Panel properly, or damage to your computer
and equipment could result.

!

Auto Mode

Manual Mode

Fan Power %

Total CFM

Fan RPM

0 - 35ºC (32 - 95ºF)

1

30

56

720

36 - 37ºC (97 - 99ºF)

2

35

66

840

38 - 39ºC (100 - 102ºF)

3

40

75

960

40 - 41ºC (104 - 106ºF)

4

45

85

1080

42 - 43ºC (108 - 109ºF)

5

50

94

1200

44 - 45ºC (111 - 113ºF)

6

60

113

1440

46 - 47ºC (115 - 117ºF)

7

70

132

1680

48 - 49ºC (118 - 120ºF)

8

80

150

1920

50 - 51ºC (122 - 124ºF)

9

90

169

2160

52 - 99ºC (126 - 210ºF)

10

100

188

2400

Sensor Channel