User Manual

Positioning the Unit

The cooling unit is designed to operate in one orientation. In other directions, the
pump and reservoir may not bleed properly and could lead to cavitation.

YES

NO

Installation

Chapter

2

Installation

Reservoir & Pump Connections

POWER: Connection from
power supply, 12VDC

FAN: Radiator fan connections
(2.0A max per plug, 3.0A total)

TEMP: Temperature sensors
shown on the front display

ATX: Wire lead for safety shutdown relay. For
computer use, leave the 2-pin wire connected
to “NO” (Normally Open) pins.

If this unit’s relay feature (see: “Alarm and
Shutdown Settings”, pg.4) will be used for an
application requiring a Normally Closed circuit,
move wire lead to “NC”.

IN/OUT: Liquid nozzle sockets

The rear of the unit accepts various connections to integrate with your cooling
system.

PUMP:
Internal pump connection

Advertising