Koolance RP-1200 Rev-2-0 User Manual

Reservoir & pump connections, Troubleshooting

Advertising
background image

Reservoir & Pump Connections

POWER: Connection from
power supply, 12VDC

FAN: Radiator fan connections
(2.0A max per plug, 4.5A total)

TEMP: Temperature sensors
shown on the front display

IN/OUT: Liquid nozzle sockets

The rear of the unit accepts various connections to integrate with your cooling
system.

PUMP:
Internal
pump

INS-FM17/INS-FM16:
Connect an optional
flow meter to display
flow rate

ON/SYNC/OFF:
Adjusts LED lighting
of INS-FM16 flow
meter

ATX: Wire lead for safety shutdown relay. For computer use,
leave the 2-pin wire connected to “NO” (Normally Open) pins.

If this unit’s relay feature (see: “Alarm and Shutdown Settings”,
pg.4) will be used for an application requiring a Normally Closed
circuit, move wire lead to “NC”.

RP-1200 Rev. 2.0 User Manual Addendum

Your product may have been updated after the user manual was printed. Please
use the below information to supplement the user manual.

Troubleshooting

5. My system has boot-up problems, or does not turn on...

Make sure the ATX wire lead is connected to “NO” (Normally Open) on the rear
of the unit. (See: “Reservoir and Pump Connections” for details.)

If this does not solve the issue, it is unrelated to the Koolance unit. In a computer,
a problem with the RAM, motherboard, power supply, video card, processor, or
monitor can cause the system to appear not to boot-up properly.