Scan mode – Belkin OMNIVIEW P72114 User Manual

Page 7

Advertising
background image

Connecting one OmniView into another is just like connecting a computer into an OmniView. The cable kit

used is the A3X982, plus an F2N209-xx-T if a serial mouse is present. Simply connect the cascaded

OmniView’s console port to one of its “parent” OmniView’s free ports, as below:

Usage:

Selecting which computer to operate can be done in two different ways - either by pressing the front-panel

pushbuttons, or by entering the hot-key sequence.

Pressing the pushbuttons in front directly switches to the selected port on the OmniView, as shown by

the solid green light on either Port #1 or #2.

To select a computer on cascaded OmniViews, press the button to select the port where the cascaded

OmniView is connected. Then, select the port on the cascaded OmniView where the desired computer

is connected.







Entering the hot-key sequence allows direct port access from the keyboard, even through cascaded

OmniViews. The procedure is very simple, and easy to remember:

1. Press <ALT>+<CTRL>+<SHIFT> all at the same time, then release.

2. Press the port number of the computer you wish to control. If you have cascaded OmniViews,

you will have to press two (or three) numbers,

x y z, where x is the port on the top level

OmniView,

y is the port on the second level OmniView, and z is the port on the third level

OmniView. Press the correct key (or keys in succession), then release.

3. Press <ENTER>, then release.

You should hear a beep to confirm the OmniView has switched to the desired port. For example,

pressing <ALT>+<CTRL>+<SHIFT> 1 2 3 <ENTER> selects Port 1 on the top level OmniView, Port 2

on the second level OmniView, and Port 3 on the third level OmniView. The OmniView filters out the

hot-key sequences, preventing unwanted characters from appearing in the computer’s applications.

Scan Mode

The OmniView can be set for automatic scan mode. In scan mode, the OmniView switches from one

computer to the next in regular time intervals set by the DIP switches. When the OmniView is in scan

mode, there is no keyboard control passed to the displayed computers. This is necessary because

switching is handled by the OmniView, not the operator.

Note: Scan mode will continue indefinitely, until the <SPACE> bar is pressed and scan mode is terminated.

Also, the OmniView will only scan to ports that have computers enabled on it.

Advertising